MARINE ALARM PANEL

INSTRUCTIONS

The panel will give a rapid warning of an extinguisher discharge or a rapid signal from the heat detector. It will monitor up to 2 zones. It is suitable for 12 or 24 volt systems.


INSTALLATION

A Control Box

Remove the four fixing screws and gently lift front panel by easing the grommets out of their slots. Fix the box in position using the screws supplied. Drill 2 x 4mm diameter holes adjacent to the ends of the box to enable the cables to feed through behind the panel.
Re-fit the panel to the box ensuring grommets fit snugly, and taking care not to strain the cables.

B Pressure Switch

Wire pressure switch once panel and AU wiring are firmly fixed.

C Sensor

Fit sensor as near as possible to engine and wire accordingly.


CONNECTION

Power input Output to Extinguishers

Red and Blue +ve Red / Blue Sensor 1
Green -ve Yellow / Green Sensor 2

Fuse

100mA for 12 volt systems, 200mA for 24 volt systems.


NOTE : When installing, please ensure that the display is located a minimum on 1m away from radar sets, VHF and other electronic and radio equipment. Please also ensure that the cable to the sensor is routed away from likely sources of interference.


OPERATION

When power is available the “Power” LED will be on.
The “Test” button will confirm the system is operational by illuminating the “Zone” LED’s and sounding the alarm.


DIMENSIONS

The dimensions of the panel are :-
Height 50mm
Length 75mm
Width 25mm.